| Type of Protection | Ex d op is (Flameproof, Inherently Safe, Optical Radiation) |
| Area Classification | Zone 0 (fibre optic cable), Zone1 and Zone 2 areas |
| ATEX Classification | Group II Category 2G |
| IEC Ex | Pending |
| ATEX | EC Type Examination Certificate Baseefa08ATEX0008X |
| Coding | Ex d op is IIB T4 Tamb 35°C |
| Enclosure | Aluminium alloy LM6 to BS 1490
All fastenings stainless steel |
| Entry | 2 x M20 cable entries for mains supply
1 x M20 for interconnection |
| Termination | 3 core 6mm sq max conductor with looping for mains supply |
| Installation | Enclosure: Flat straps or via M8 bosses on rear
Fibre Optics: Accessories Available |
| Relamping | Simple plug arrangement with no special knowledge required |
| Burning Position | Universal |
| Ingress Protection | IP66/67 |
| Electrical Supply | 110-254V 50/60Hz |
| Battery | Li-ion |
| Duration | 90 minutes |
| Emergency Output | 100% |